THREE-PHASE · LOAD BALANCING

Three-phase supply: room for larger appliances, EV charging and solar

Explore how separate circuits can use different phases. A large single-phase appliance still uses one phase; unused capacity on B or C does not automatically help an overloaded A.

Teaching example — not your approved connection capacity

Both cases use the same current limit per phase, 230 V phase-to-neutral and power factor 1. All entered loads are assumed simultaneous. Real supply limits, diversity, starting current, cable protection and network approval must be assessed separately.

Three single-phase appliance examples — edit their actual input power

The 3 kW presets are illustrative, not appliance specifications. Use the rated electrical input or an assessed simultaneous demand. Each appliance stays wholly on its assigned phase.

Air conditioner
Kitchen appliance
Water heater

Assignments are a simulation, not wiring instructions. Only a licensed electrician can assess or change circuit arrangements.

Actual charging is limited by the vehicle’s onboard charger, EVSE, wiring, approved supply and load management. The 11/22 kW options require a compatible three-phase setup; grid power may supply EV demand independently of inverter output.

Single phase · all requested demand on A

7.36 kW illustrative supply limit

230 V × 32 A ÷ 1,000

Single-phase requested-demand comparison
PhaseRequested loadCurrent at PF 1Remaining / over limit
A9 kW 39.13 AOver by 1.64 kW Over illustrative limit

Three phases · check A, B and C separately

22.08 kW aggregate illustration only

3 × 230 V × 32 A ÷ 1,000 · 7.36 kW / phase

Assigned three-phase requested demand
PhaseRequested loadCurrent at PF 1Remaining / over limit
A3 kW 13.04 ARemaining 4.36 kW Within illustrative limit
B3 kW 13.04 ARemaining 4.36 kW Within illustrative limit
C3 kW 13.04 ARemaining 4.36 kW Within illustrative limit

Every phase is within this simplified example limit. This is not a safety or connection approval.

The same total requested load is compared in both cases: 9 kW. Three phases do not reduce an appliance’s energy use or automatically triple an existing home’s approved capacity.

Inverter output is separate from supply headroom

Inverter generation is NOT subtracted from appliance demand to claim extra protective headroom. Solar output varies; actual inverter, per-phase export limits, voltage-rise compliance and cable upgrades require network and installer assessment. Three-phase supply/inverters do not guarantee stable voltage or whole-home backup during an outage.

Optional financial scenario — your own supported inputs

Phase count alone creates no assumed bill saving. Enter only a documented annual operational benefit, such as an assessed avoided operational cost; describe its basis. The description is not independently verified by this tool.

Annual net scenario benefit = entered benefit − recurring cost: A$0

No positive annual net benefit; no payback is calculated.

Simple payback = upfront cost ÷ positive annual net benefit. Money is rounded to cents. This is not a quote or investment recommendation; financing, tax, changing tariffs and future performance are not modelled.

All inputs stay on this page; nothing is saved or sent. Ask your licensed electrician, installer and electricity network about the actual connection, phase balancing, EV load management and protection. Do not change wiring yourself.

Call FH1300 026 666

A little surprise for you

One surprise per member, shared across FH and G.T.E.

For service or installation fees only. Not redeemable for cash. Any discount is capped at the eligible fee. Contact us before the expiry date to redeem.